Rating: 550 LPM, 150 psi (10.3 bar, 1034 kPa)
Flange: 2″
Meter Construction: Aluminum
Seals: Buna/Viton®as noted by catalog number
Maximum Pressure: 150psi (as listed by catalog number)
Temperature: -40° to 185° F
Meter Classes | Description | Bearing Material |
---|---|---|
1 | Refined petroleum products | Ni-Resist* |
2 | Aviation and jet fuel | Ni-Resist* |
*(carbon bearings are standard on some meter sizes of this class, please consult factory)
M10A1
METER WITH REGISTRATION
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
SOFTWARE |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
||||||
M10A1-LCR.IQ-I#1 |
L-R |
LITRES |
BUNA |
N/A |
OIML |
|
LCR®-II REGISTRATION |
||||||
M10A1-LCR2-I#1 |
L-R |
1/10 GAL |
VITON® |
SL200 ST215 |
NIST |
|
MECHANICAL REGISTRATION |
||||||
M10A1-MECH-NP#1 |
L-R |
LITRES |
BUNA |
N/A |
AUST |
|
M10A1-MECH-NP#2 |
L-R |
1/10 GAL |
BUNA |
N/A |
NIST |
|
SETUP FOR ELECTRONIC REGISTRATION |
||||||
M10A1-SUFE#1 |
L-R |
WH GAL |
BUNA |
N/A |
NIST |
|
MD10A1-SUFE#1 |
L-R |
LITRES |
BUNA |
N/A |
CAN |
|
MR10A1-SUFE#1 |
L-R |
LITRES |
BUNA |
N/A |
CAN |
M10C1
METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
STRAINER TYPE |
MESH |
AIR ELIMINATOR |
CHECK VALVE |
TEMP COMP |
SOFTWARE |
W&M |
|
LCR.iQ® REGISTRATION |
|||||||||||
M10C1-LCR.IQ-I#1 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M10C1-LCR.IQ-I#2 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10CT1-LCR.IQ-I#1 |
R-L |
WH GAL |
BUNA |
STD |
40 |
MECH |
SOFT OUTLET |
YES |
N/A |
NIST |
|
LCR®-II REGISTRATION |
|||||||||||
M10C1-LCR2-I#1 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
SL201 ST204 |
NIST |
|
LCR®600 REGISTRATION |
|||||||||||
M10C1-LCR600-I#1 |
L-R |
1/10 GAL |
BUNA |
HI CAP |
40 |
MECH |
SOFT OUTLET |
N/A |
SL600 ST662 |
NIST |
|
M10C1-LCR600-I#2 |
R-L |
1/10 GAL |
BUNA |
HI CAP |
40 |
MECH |
SOFT OUTLET |
N/A |
SL600 ST662 |
NIST |
|
M10C1-LCR600-I#3 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
NA |
N/A |
SL601 ST603 |
NIST |
|
LESS MECHANICAL REGISTER |
|||||||||||
M10C1-LR#1 |
L-R |
1/10 GAL |
BUNA |
HI CAP |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-LR#3 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
AUST |
|
M10C1-LR#4 |
L-R |
LITRES |
VITON® |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M10C1-LR#5 |
L-R |
1/10 GAL |
VITON® |
HI CAP |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
M10C1
METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
STRAINER TYPE |
MESH |
AIR ELIMINATOR |
CHECK VALVE |
TEMP COMP |
SOFTWARE |
W&M |
|
MECHANICAL REGISTRATION |
|||||||||||
M10C1-MECH-NP#1 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-MECH-NP#3 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-MECH-NP#4 |
L-R |
1/10 GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-MECH-NP#5 |
L-R |
1/10 GAL |
VITON® |
HI CAP |
40 |
MECH |
METAL INLET |
N/A |
N/A |
NIST |
|
M10C1-MECH-NP#6 |
R-L |
1/10 GAL |
VITON® |
HI CAP |
40 |
MECH |
METAL INLET |
N/A |
N/A |
NIST |
|
M10C1-MECH-NP#7 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M10C1-MECH-NP#8 |
L-R |
LITRES |
VITON® |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M10C1-MECH-NP#10 |
R-L |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M10CX1-MECH-NP#1 |
L-R |
LITRES |
BUNA |
HI CAP |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
POD (PULSE OUTPUT DEVICE) |
|||||||||||
M10C1-POD#2 |
L-R |
1/10 GAL |
BUNA |
HI CAP |
40 |
MECH |
METAL INLET |
N/A |
N/A |
NIST |
|
M10CX1-POD#1 |
L-R |
1/10 GAL |
BUNA |
HI CAP |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
SETUP FOR ELECTRONIC REGISTRATION |
|||||||||||
M10C1-SUFE#1 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-SUFE#2 |
R-L |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-SUFE#3 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-SUFE#4 |
R-L |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-SUFE#5 |
L-R |
WH GAL |
BUNA |
HI CAP |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-SUFE#6 |
R-L |
WH GAL |
BUNA |
HI CAP |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M10C1-SUFE#8 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
AUST |
|
M10CT1-SUFE#1 |
L-R |
WH GAL |
BUNA |
HI CAP |
40 |
OPTICAL |
SOFT INLET |
YES |
N/A |
NIST |
|
M10G1 METER WITH REGISTER + STRAINER + AIR ELIMINATOR + PRINTER
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
STRAINER TYPE |
MESH |
AIR |
CHECK VALVE |
PRINTER TYPE |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|
|||||||||
M10G1-MECH-NP#1 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
FACE DOWN |
NIST |
|
M10G1-MECH-NP#2 |
L-R |
1/10 GAL |
VITON® |
HI CAP |
40 |
MECH |
METAL INLET |
FACE DOWN |
NIST |
|
M10G1-MECH-NP#3 |
R-L |
1/10 GAL |
VITON® |
HI CAP |
40 |
MECH |
METAL INLET |
FACE DOWN |
NIST |
|
M10K1
METER WITH REGISTRATION + PRESET VALVE + STRAINER + AIR ELIMINATOR.
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
CHECK VALVE |
TEMP COMP |
SOFTWARE |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
|||||||||||||
M10K1-LCR.IQ-E#1 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#3 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#4 |
L-R |
1/10 GAL |
BUNA |
EP7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#5 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#6 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
UP (ELBOW) |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#7 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
UP (ELBOW) |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#8 |
L-R |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#9 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
OIML |
|
M10K1-LCR.IQ-I#10 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#12 |
R-L |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#13 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
STD |
40 |
MECH |
METAL INLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#16 |
L-R |
1/10 GAL |
BUNA |
EP7 |
UP |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
NIST |
|
M10K1-LCR.IQ-I#17 |
R-L |
1/10 GAL |
BUNA |
EP7 |
UP |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
N/A |
NIST |
|
M10KT1-LCR.IQ-I#1 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT INLET |
YES |
N/A |
NIST |
|
M10KT1-LCR.IQ-I#2 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT INLET |
YES |
N/A |
NIST |
|
MD10KT1-LCR.IQ-I#1 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
N/A |
YES |
N/A |
CANADA |
|
MD10KT1-LCR.IQ-I#2 |
R-L |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
YES |
N/A |
CANADA |
|
MD10KT1-LCR.IQ-I#3 |
R-L |
LITRES |
BUNA |
BLOCK |
UP (ELBOW) |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
YES |
N/A |
CANADA |
|
MR10KT1-LCR.IQ-I#1 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
N/A |
YES |
N/A |
CANADA |
|
MR10KT1-LCR.IQ-I#2 |
R-L |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
N/A |
YES |
N/A |
CANADA |
|
MR10KT1-LCR.IQ-I#4 |
R-L |
LITRES |
BUNA |
BLOCK |
UP (ELBOW) |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
YES |
N/A |
CANADA |
|
MR10KY1-LCR.iQ-I#1 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
MECH |
N/A |
YES |
N/A |
CANADA |
M10K1 CONTINUED
METER WITH REGISTRATION + PRESET VALVE + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
CHECK VALVE |
TEMP COMP |
SOFTWARE |
W&M APPROVAL |
|
LCR®600 R EGISTRATION |
|||||||||||||
M10K1-LCR600-I#3 |
R-L |
1/10 GAL |
BUNA |
EP7 |
UP |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL600 ST662 |
NIST |
|
M10K1-LCR600-I#6 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL600 ST662 |
NIST |
|
M10K1-LCR600-I#7 |
L-R |
1/10 GAL |
BUNA |
EP7 |
UP |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL600 ST662 |
NIST |
|
M10K1-LCR600-I#8 |
L-R |
1/10 GAL |
BUNA |
EP7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL600 ST662 |
NIST |
|
M10K1-LCR600-I#11 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL600 ST662 |
NIST |
|
M10K1-LCR600-I#18 |
L-R |
1/10 GAL |
BUNA |
E7 |
UP |
STD |
40 |
MECH |
SOFT INLET |
N/A |
SL600 ST600 |
NIST |
|
M10K1-LCR600-I#19 |
R-L |
1/10 GAL |
BUNA |
E7 |
UP |
STD |
40 |
MECH |
SOFT INLET |
N/A |
SL600 ST600 |
NIST |
|
M10K1-LCR600-I#20 |
L-R |
1/10 GAL |
BUNA |
E7 |
UP |
STD |
40 |
OPTICAL |
SOFT INLET |
N/A |
SL600 ST600 |
NIST |
|
LCR®-II REGISTRATION |
|||||||||||||
M10K1-LCR2-E#1 |
L-R |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST215 |
NIST |
|
M10K1-LCR2-E#2 |
R-L |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST215 |
NIST |
|
M10K1-LCR2-I#2 |
L-R |
1/10 GAL |
BUNA |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
N/A |
N/A |
SL200 ST200 |
NIST |
|
M10K1-LCR2-I#3 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL200 ST202 |
NIST |
|
M10K1-LCR2-I#5 |
L-R |
1/10 GAL |
BUNA |
E7 |
UP |
STD |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST200 |
NIST |
|
M10K1-LCR2-I#7 |
L-R |
1/10 GAL |
VITON® |
E7 |
DOWN |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST215 |
NIST |
|
M10K1-LCR2-I#10 |
L-R |
WH GAL |
VITON® |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST200 |
NIST |
|
M10K1-LCR2-I#12 |
R-L |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST258 |
NIST |
|
M10K1-LCR2-I#14 |
L-R |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST258 |
NIST |
|
M10K1-LCR2-I#15 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL200 ST258 |
NIST |
|
M10K1-LCR2-I#16 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL200 ST258 |
NIST |
M10K1 CONTINUED
METER WITH REGISTRATION + PRESET VALVE + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
CHECK VALVE |
TEMP COMP |
SOFTWARE |
W&M APPROVAL |
|
LCR®-II REGISTRATION |
|||||||||||||
M10K1-LCR2-I#17 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
N/A |
N/A |
SL200 ST202 |
NIST |
|
M10K1-LCR2-I#19 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
UP (ELBOW) |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
N/A |
SL200 ST258 |
NIST |
|
M10K1-LCR2-I#20 |
L-R |
WH GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST258 |
NIST |
|
M10K1-LCR2-I#25 |
L-R |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST215 |
NIST |
|
M10K1-LCR2-I#26 |
R-L |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST215 |
NIST |
|
M10K1-LCR2-I#27 |
L-R |
1/10 GAL |
BUNA |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
N/A |
SL200 ST258 |
NIST |
|
M10K1-LCR2-I#28 |
R-L |
1/10 GAL |
BUNA |
E7 |
UP |
STD |
40 |
MECH |
METAL INLET |
N/A |
SL200 ST215 |
NIST |
|
M10KT1-LCR2-I#2 |
L-R |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT INLET |
YES |
SL200 ST228 |
NIST |
|
M10KT1-LCR2-I#3 |
R-L |
1/10 GAL |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT INLET |
YES |
SL200 ST228 |
NIST |
|
M10KT1-LCR2-I#4 |
L-R |
1/10 GAL |
VITON® |
E7 |
UP |
HI CAP |
40 |
OPTICAL |
METAL INLET |
YES |
SL200 ST215 |
NIST |
|
M10KT1-LCR2-I#5 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
N/A |
YES |
SL200 ST215 |
OIML |
|
MR10KT1-LCR2-I#1 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
N/A |
YES |
SL200 ST200 |
CANADA |
|
MR10KT1-LCR2-I#2 |
R-L |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
YES |
SL200 ST201 |
CANADA |
|
MR10KT1-LCR2-I#3 |
R-L |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
N/A |
YES |
SL200 ST200 |
CANADA |
|
MR10KT1-LCR2-I#4 |
R-L |
LITRES |
BUNA |
BLOCK |
UP (ELBOW) |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
YES |
SL202 ST201 |
CANADA |
|
MR10KT1-LCR2-I#7 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT INLET |
YES |
SL200 ST200 |
CANADA |
|
MR10KT1-LCR2-I#8 |
L-R |
LITRES |
BUNA |
BLOCK |
INLINE |
HI CAP |
40 |
OPTICAL |
SOFT OUTLET |
YES |
SL200 ST200 |
CANADA |
|
M10K1 CONTINUED
METER WITH REGISTRATION + PRESET VALVE + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
CHECK VALVE |
TEMP COMP |
SOFT WARE |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||||||
M10K1-MECH-NP#1 |
L-R |
1/10 GAL |
VITON® |
4 DIGIT |
MECH |
UP |
HI CAP |
40 |
MECH |
METAL INLET |
N/A |
NIST |
|
M10K1-MECH-NP#2 |
L-R |
1/10 GAL |
BUNA |
4 DIGIT |
MECH |
UP |
STD |
40 |
MECH |
N/A |
N/A |
NIST |
|
M10N1
METER WITH REGISTRATION + PRESET VALVE + STRAINER + AIR ELIMINATOR + PRINTER
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
PRESET TYPE |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
CHECK VALVE |
PRINTER TYPE |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||||||
M10N1-MECH-NP#1 |
L-R |
1/10 GAL |
VITON® |
4-DIGIT |
MECH |
REAR |
HI CAP |
40 |
MECH |
METAL INLET |
FACE DOWN |
NIST |
|
M10N1-MECH-NP#2 |
R-L |
1/10 GAL |
VITON® |
4-DIGIT |
MECH |
REAR |
HI CAP |
40 |
MECH |
METAL INLET |
FACE DOWN |
NIST |
|
M10N1-MECH-NP#3 |
L-R |
LITRES |
VITON® |
4-DIGIT |
MECH |
REAR |
HI CAP |
40 |
MECH |
METAL INLET |
FACE DOWN |
NIST |
|
M10P1
METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M10P1-LRG#1 |
L-R |
1/10 GAL |
BUNA |
NIST |
|
M10P1-LRG#3 |
L-R |
1/10 GAL |
VITON® |
NIST |
|
M10S1
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M10S1-POD#1 |
L-R |
WH GAL |
BUNA |
NIST |
|
M10S1-POD#2 |
L-R |
LITRES |
BUNA |
OIML |
|
M10A2 METER WITH REGISTER
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
TEMP COMP. |
SOFTWARE |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||
M10A2-MECH-NP#1 |
L-R |
285 |
WH GAL |
N |
N/A |
NIST |
|
M10A2-MECH-NP#2 |
L-R |
285 |
1/10 GAL |
N |
N/A |
NIST |
|
M10A2-MECH-WP#1* |
L-R |
285 |
WH GAL |
N |
N/A |
NIST |
|
SETUP FOR ELECTRONIC REGISTRATION |
|||||||
M10A2-SUFE#1 |
L-R |
285 |
LITRES |
N |
N/A |
OIML |
|
M10C2 METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
STRAINER TYPE |
MESH |
AIR ELIM. |
SOFTWARE |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
|||||||||
M10C2-LCR.IQ-I#1 |
L-R |
150 |
LITRES |
STD |
40 |
MECH |
N/A |
NIST |
|
MECHANICAL REGISTRATION |
|||||||||
M10C2-MECH-NP#1 |
L-R |
150 |
LITRES |
STD |
40 |
MECH |
N/A |
NIST |
|
M10C2-MECH-NP#2 |
L-R |
150 |
LITRES |
STD |
40 |
MECH |
N/A |
AUST |
|
M10C2-MECH-NP#3 |
L-R |
150 |
LITRES |
STD |
40 |
MECH |
N/A |
NIST |
M10K2 METER WITH REGISTER + STRAINER + AIR ELIMINATOR + PRESET VALVE
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
PRESET TYPE |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||||
M10K2-MECH-NP#1 |
L-R |
150 |
LITRES |
4-digit |
MECH |
UP |
STD |
40 |
MECH |
AUST |
|
M10P2 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
LESS REGISTER & GEAR PLATE |
|||||
M10P2-LRG#1 |
L-R |
285 |
1/10 |
NIST |
|
M10S2 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
TEMP COMP. |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
||||||
M10S2-POD#1 |
L-R |
285 |
WH GAL |
N |
NIST |
|
M10S2-POD#2 |
L-R |
285 |
LITRES |
N |
AUS |
|
M10S2-POD#3 |
L-R |
285 |
LITRES |
N |
INMETRO |
Use the chart below to determine maximum meter flow rate relative to meter bearing material and product viscosity:
If the plotted point is above the bearing material slope, you are outside the allowable pressure loss for the specified meter and bearing. You should either chose a larger meter, reduce flow rate, or consider alternative bearing materials.