Rating: 1325 LPM, 150 psi (10.3 bar, 1034 kPa)
Flange: 4″
Meter Construction: Aluminum
Seals: Buna/Viton® as noted by catalog number
Maximum Pressure: 150psi (as listed by catalog number)
Temperature: -40° to 185° F
Bearing Material Recommended: Ni-Resist (carbon bearings are standard on some meter sizes of this class, please consult factory)
Meter Classes | Description | Bearing Material |
---|---|---|
1 | Refined petroleum products | Ni-Resist* |
2 | Aviation and jet fuel | Ni-Resist* |
14 | Crude oil | Ni-Resist* |
16 | General solvents | Carbon |
*(carbon bearings are standard on some meter sizes of this class, please consult factory)
M30A1 METER WITH REGISTRATION
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
TEMP. COMP. |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
||||||
M30A1-LCR.iQ-I#1 |
L-R |
LITRES |
BUNA |
N/A |
OIMIL |
|
MECHANICAL REGISTRATION |
||||||
M30A1-MECH-NP#1 |
L-R |
LITRES |
BUNA |
N/A |
NIST |
|
M30A1-MECH-NP#2 |
L-R |
WH GAL |
BUNA |
N/A |
NIST |
|
M30AT1-MECH-NP#1 |
L-R |
WH GAL |
BUNA |
YES |
NIST |
M30C1 METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
STRAINER TYPE |
MESH |
AIR ELIM. |
CHECK VALVE |
TEMP. COMP. |
SOFTWARE |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
|||||||||||
M30C1-LCR.iQ-I#1 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
LCR®-II REGISTRATION |
|||||||||||
M30CY1-LCR2-I#1 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
METAL INLET |
YES |
SL200 ST200 |
NIST |
|
LCR®600 REGISTRATION |
|||||||||||
M30C1-LCR600-I#1 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
SL600 ST600 |
NIST |
|
MECHANICAL REGISTRATION |
|||||||||||
M30C1-MECH-NP#2 |
L-R |
IMP GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M30C1-MECH-NP#3 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M30C1-MECH-NP#4 |
L-R |
DEKALITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M30C1-MECH-NP#5 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
CAN |
|
M30C1-MECH-NP#6 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M30C1-MECH-NP#9 |
L-R |
LITERS |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
SET UP FOR ELECTRONICS |
|||||||||||
M30C1-SUFE#1 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M30C1-SUFE#2* |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
*INCLUDES METAL INLET CHECK
M30G1 METER WITH REGISTER + PRINTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
PRESET TYPE |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
W&M APPROVAL |
MECHANICAL REGISTRATION |
||||||||||
M30G1-MECH-NP#2 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
M30K1
METER WITH REGISTER + PRESET VALVE + PRESET + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
PRESET TYPE |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||||
M30K1-MECH-NP#2 |
L-R |
IMP GAL |
BUNA |
5-DIGIT |
MECH |
REAR |
STD |
40 |
MECH |
OIML |
|
M30K1-MECH-NP#4 |
L-R |
LITRES |
VITON® |
5-DIGIT |
MECH |
REAR |
STD |
40 |
MECH |
OIML |
|
M30K1-MECH-NP#8 |
L-R |
LITRES |
BUNA |
5-DIGIT |
MECH |
REAR |
STD |
40 |
MECH |
NIST |
M30P1
METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M30P1-LRG#1 |
L-R |
LITRES |
VITON® |
OIML |
|
M30P1-LRG#2 |
L-R |
WH GAL |
VITON® |
NIST |
|
M30P1-LRG#3 |
L-R |
LITRES |
VITON® |
CAN |
|
M30P1-LRG#4 |
L-R |
WH GAL |
BUNA |
NIST |
|
M30P1-LRG#5 |
L-R |
LITRES |
BUNA |
CAN |
M30S1
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M30S1-POD#1 |
L-R |
WH GAL |
BUNA |
NIST |
|
M30S1-POD#2 |
L-R |
LITRES |
BUNA |
CAN |
|
M30S1-POD#3 |
L-R |
LITRES |
VITON® |
CAN |
M30A2 M30 METER WITH REGISTER
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
TEMP COMP. |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
||||||
M30A2-LCR.IQ-I#1 |
L-R |
150 |
WH GAL |
N |
NIST |
|
MECHANICAL REGISTRATION |
||||||
M30A2-MECH-NP#2 |
L-R |
150 |
WH GAL |
N |
NIST |
|
M30A2-MECH-NP#5*** |
L-R |
150 |
DEKALITRES |
N |
OIML |
|
M30AT2-MECH-NP#1 |
R-L |
150 |
WH GAL |
Y |
NIST |
|
M30AT2-MECH-NP#2 |
L-R |
150 |
WH GAL |
Y |
NIST |
|
M30AT2-MECH-NP#3 |
L-R |
150 |
LITRES |
Y |
NIST |
|
M30AT2-MECH-NP#4 |
R-L |
150 |
LITRES |
Y |
NIST |
|
M30AT2-MECH-WP#2** |
R-L |
150 |
WH GAL |
Y |
NIST |
**PROVIDED WITH 100 PPR SOLID STATE PULSER
***VITON® ELASTOMERS
M30C2 M30 METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
STRAINER TYPE |
MESH |
AIR ELIM. |
TEMP COMP. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||
M30CT2-MECH-NP#1 |
L-R |
150 |
LITRES |
STD |
40 |
MECH |
Y |
OIML |
|
M30C2-MECH-NP#1 |
L-R |
150 |
WH GAL |
STD |
40 |
MECH |
N |
NIST |
M30P2
M30 METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M30P2-LRG#1 |
L-R |
150 |
WH GAL |
NIST |
M30S2
M30 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M30S2-POD#1 |
L-R |
150 |
LITRES |
CAN |
M40A2
METER WITH REGISTERATION
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
TEMP COMP. |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
||||||
M40A2-LCR.IQ-I#1 |
L-R |
150 |
WH GAL |
N |
NIST |
|
M40A2-LCR.IQ-E#1* |
L-R |
150 |
LITRES |
N |
OIML |
|
M40AT2-LCR.IQ-I#1 |
L-R |
150 |
WH GAL |
Y |
NIST |
|
MECHANICAL REGISTRATION |
||||||
M40A2-MECH-NP#1 |
L-R |
150 |
WH GAL |
N |
NIST |
|
M40AT2-MECH-NP#1 |
L-R |
150 |
WH GAL |
Y |
NIST |
|
SETUP FOR ELECTRONIC REGISTRATION |
||||||
M40A2-SUFE#1 |
L-R |
150 |
WH GAL |
N |
NIST |
M40C2 METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
STRAINER TYPE |
MESH |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||
M40C2-MECH-NP#1 |
L-R |
150 |
WH GAL |
STD |
40 |
NIST |
M40E2 METER WITH REGISTER + PRINTER
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
MESH |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
||||||
M40E2-MECH-NP#1 |
L-R |
150 |
WH GAL |
N |
NIST |
M40P2 METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M40P2-LRG#2 |
L-R |
150 |
WH GAL |
NIST |
M40S2 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M40S2-POD#1 |
L-R |
150 |
WH GAL |
NIST |
M30A14
METER WITH REGISTER
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
|
LCR.iQ® REGISTRATION |
||||
M30A14-MECH-NP#1 |
L-R |
WH. GAL |
VITON |
|
M30A14-MECH-NP#2 |
L-R |
DEKALITRES |
VITON |
M30C14
METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
STRAINER TYPE |
MESH |
AIR ELIM. |
|
MECHANICAL REGISTRATION |
|||||||
M30C14-MECH-NP#1* |
L-R |
WH. GAL |
VITON |
STANDARD |
40 |
MECH |
|
M30C14-MECH-NP#2* |
L-R |
LITRES |
VITON |
STANDARD |
20 |
MECH |
*SUPPLIED WITH 1-FOOT HEAT EXTENSION
M30P14
METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
|
LESS REGISTER & GEAR PLATE |
||||
M30P14-LRG#1 |
L-R |
WH. GAL |
VITON |
M30S14
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
|
POD (PULSE OUTPUT DEVICE) |
||||
M30S14-POD#1 |
L-R |
WH. GAL |
VITON |
M30K16
METER WITH REGISTER + PRESET VALVE + PRESET + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
PRESET |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||||
M30K16-MECH-NP#1 |
L-R |
LITRES |
PTFE |
5-DIGIT |
MECH |
FRONT |
STD |
40 |
MECH |
NIST |
|
M30S16
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M30S16-POD#1 |
L-R |
LITRES |
PTFE |
OIML |
|
Use the chart below to determine maximum meter flow rate relative to meter bearing material and product viscosity:
If the plotted point is above the bearing material slope, you are outside the allowable pressure loss for the specified meter and bearing. You should either chose a larger meter, reduce flow rate, or consider alternative bearing materials.