Direct reading with a single jet, wet dial, and a lid that rotates 360 degrees and has an anti-fraud ring.
Produced in cold and hot water versions with sizes DN15 and DN20 mm (1/2′′- 3/4′′).
Using inductive pre-equipment, data transmission modules for M-BUS wired and wireless, non-magnetic pulse output, and LoRa can be installed.
Size |
DN (inch) |
15 (1/2") |
20 (3/4") |
||
Overload flow rate |
Q4 |
m³/h |
3.12 |
5 |
|
Permanent flow rate |
Q3 |
m³/h |
2,5 |
4 |
|
R=100 VH ↑→ |
Transitional flow rate |
Q2 |
L/h |
40 |
64 |
Min flow rate |
Q1 |
L/h |
25 |
40 |
|
R=160 H ↑ |
Transitional flow rate |
Q2 |
L/h |
25 |
40 |
Min flow rate |
Q1 |
L/h |
15,63 |
25 |
|
Min reading |
L |
0,05 |
|||
Max reading |
m³ |
99.999 |
|||
Max admissible pressure MAP |
bar |
16 |
Size |
DN (inch) |
15 (1/2") |
20 (3/4”) |
|
L |
mm |
110 |
130 |
|
I |
mm |
190 |
228 |
|
H |
mm |
77 |
81 |
|
h |
mm |
13 |
17 |
|
B |
mm |
80 |
80 |
|
Threading |
in |
3/4" |
1" |
|
Weight |
with unions |
Kg |
0,76 |
0,93 |
without unions |
Kg |
0,62 |
0,69 |