Nitto Seiko Mass Flow Meter

A mass flow metre called CLEAN FLOW achieves great performance and high dependability. By sensing the phase difference created by Coriolis in the measuring tube, it is able to measure mass flow directly. An easy-to-use capacitance touch panel is a feature of the high-functioning transmitter. A variety of indication articles can be put on the three LCD lines.


  • badge1 Original Products
  • badge2 Warranty Against Defects
  • badge3 Returns & Refunds Policy
  • badge4 Ships Worldwide
  • badge5 Dedicate Support
  • Features
  • Specifications
  • Flow
  • Pressure loss
  • External dimensions
  • Transmitter
  • Specification code
  • It can measure mass flow directly, it is not affected temperature, pressure, viscosity, density, or flow distribution due to its measurement
  • Compact design
  • It does not need special fixture. Easy
  • New type measuring tube realizes low pressure
  • Various indication article by 3 line
  • Good visibility by Buck-light
  • Plug-in card can add out/input easily. (Option)

Sensor

Size

015

025

050

080

100

150

Nominal diameter

10A, 15A, 20A, 25A, 40A, 50A, 65A, 80A, 100A, 150A, 200A

 

Connection end

JIS10K, 20K

ASME/ANSI 150, 300, 600 JPI 150, 300, 600

DIN PN16, 40, 63 Tri-clamp

Fluid

Liquid/Gas

Flow range

0 ~ 860,000 Kg/h (6 type)

Accuracy

 

 

Volume

 

Liquid

General:                               Mass flow                             ±0.4%

Volume flow                         ±0.4%

High accuracy:                    Mass flow                            ±0.15% (±0.1%option)

Volume flow                         ±0.15%

Gas

General:                               Mass flow                            ±1.0%

High accuracy:                    Mass flow                            ±0.5%

Density

Liquid

General:                               0.010kg/L

High accuracy:                    0.002kg/L (0.001kg/L option)

 

Temperature

General:                               -50 ~ 160 ℃

High accuracy:                    -50 ~ 205 ℃

Explosion-proof type is depending on the specification

Pressure

Depending on the connection end

Wetted parts material

Stainless steel (Standard), Alloy C (Option)

Explosion-proof

ATEX / IECEx, cFMus,

TIIS (Applying)

Transmitter

Power

100 ~ 240V AC, 50/60Hz

11 ~ 30V DC

Power consumption

20W

Protection level

Unit type     : IP65 / IP67, NEMA 4X

Remote type: IP65 / IP67 / IP68 (Sensor only, Immersion depth 5m), NEMA 4X

Housing material

Aluminum

Stainless (Remote type: Option)

 

Output signal

Analog: 4-20mA DC (Active mode or Passive mode)

Digital: 2 points (Pulse or switch) (Passive mode) HART (Protocol Ver. 7.1)

Dumping

0.8 sec. (Avilable setting 0.2 ~100 sec)

Low cut-off

1% of Max. flow rate. (Available setting 0~5%)

Transmission distance

Max. 200m (Remote type)

Liquid mesurement

Size

015

025

050

080

100

150

Flow range

MASS flow[kg/h]

0~8,000

0~35,000

0~90,000

0~250,000

0.~560,000

0~860,000

Volume flow [L/h](※1

0~8,000

0~35,000

0~90,000

0~250,000

0.~560,000

0~860,000

(※1)Volume flow is according to the 1g/mL of density. In case of other than 1mg/mL Volume flow = Mass flow / Density.

Zero-stability [kg/h]

0.64

2.16

7.2

20

41.6

68.8


Basic accuracy

Model

430 (General type)

450 (High accuracy type)

 

 

Mass flow (Liquid)

±0.4%

±0.25% (Option)

±0.20% (Option)

±0.15%

±0.10% (Option)

Mass flow (Gas)

±1.0%

±0.5%

 

 

Volume flow

±0.4%

±0.25% (Option)

±0.20% (Option)

±0.15%

Repeatibility (volume)

Refer to below table

 

Density (Liquid)

0.010kg/L

0.002kg/L

0.001kg/L

 

Repeatibility (density)

0.002kg/L

0.002kg/L

0.001kg/L


Measuring accuracy

 

Max. measuring accuracy

Repeatability

 

1

 

±General accuracy

 

±1/2×General accuracy

 

2

 

±(Zero-stability/Measured value)×100%

 

±1/2×(Zero-stability/Measured value)×100%

 

 

Meter size

Size   (mm)

Approx. weight (kg)

015

φ44.5

77

46

340

025

φ69.5

103

62

379

11

050

φ99

125

80

416

27

080

φ155

183

123

505

71

100

φ185

261

168

603

123

150

□260

320

205

691

181

Remote type

 

Meter size

Size   (mm)

Approx. weight (kg)

015

φ44.5

77

46

340

025

φ69.5

103

62

379

11

050

φ99

125

80

416

27

080

φ155

183

123

505

71

100

φ185

261

168

603

123

150

□260

320

205

691

181

015 sensor connection standard

Connection end

Specification code

L(mm)

D(mm)

10A JIS10K

015E1J1

385

90

15A JIS10K

015R0J1

385

95

1/2” CL150 (ASME B 16.5)

015R0A1

435

89

1/2” CL300 (ASME B 16.5)

015R0A3

421

95

20A JIS10K

015R1J1

421

100

3/4” CL150 (ASME B 16.5)

015R1A1

421

98

Conform to DIN 32676 1/2” Tri-clamp

015R0T1

413

34

Conform to ASME BPE 1/2” Tri-clamp

015R0T3

433

25

025 sensor connection standard

Connection end

Specification code

L(mm)

D(mm)

20A JIS10K

025E1J1

576

100

3/4” CL150 (ASME B 16.5)

025E1A1

575

98

25A JIS10K

025R0J1

525

125

1” CL150 (ASME B 16.5)

025R0A1

575

108

1” CL300 (ASME B 16.5)

025R0A3

576

124

40A JIS10K

025R2J1

576

140

1-1/2” CL150 (ASME B 16.5)

025R2A1

576

127

In accordance with DIN 32676 1” Tri-clamp

025R0T1

590

50.5

In accordance with ASME BPE 1” Tri-clamp

025R0T3

590

50.4

050 sensor connection standard

Connection end

Specification code

L(mm)

D(mm)

40A JIS10K

050E1J1

763

140

1-1/2” CL150 (ASME B 16.5)

050E1A1

763

127

1-1/2” CL300 (ASME B 16.5)

050E1A3

756

156

50A JIS10K

050R0J1

715

155

2” CL150 (ASME B 16.5)

050R0A1

715

152

2” CL300 (ASME B 16.5)

050R0A3

763

165

65A JIS10K

050R1J1

763

175

2-1/2” CL150 (ASME B 16.5)

050R1A1

756

178

In accordance with DIN 32676 2” Tri-clamp

050R0T1

740

64

In accordance with ASME BPE 2” Tri-clamp

050R0T3

740

63.9

080 sensor connection standard

Connection end

Specification code

L(mm)

D(mm)

65A JIS10K

080E1J1

910

175

2-1/2” CL300 (ASME B 16.5)

080E1A3

920

178

80A JIS10K

080R0J1

870

185

3” CL150 (ASME B 16.5)

080R0A1

880

191

3” CL300 (ASME B 16.5)

080R0A3

895

210

100A JIS10K

080R1J1

1060

210

4” CL150 (ASME B 16.5)

080R1A1

880

229

In accordance with DIN 32676 3” Tri-clamp

080R0T1

910

106

In accordance with ASME BPE 3” Tri-clamp

080R0T3

910

90.9

100 sensor connection standard

Connection end

Specification code

L(mm)

D(mm)

80A JIS10K

100E1J1

1275

185

3” CL300 (ASME B 16.5)

100E1A3

1244

210

100A JIS10K

100R0J1

1150

210

4” CL150 (ASME B 16.5)

100R0A1

1144

229

4” CL300 (ASME B 16.5)

100R0A3

1324

254

150A JIS10K

100R2J1

1300

280

6” CL150 (ASME B 16.5)

100R2A1

1330

279

Note) This size is for major item. Unavailable for manufacturing depend on the combination.

150 sensor connection standard

Connection end

Specification code

L(mm)

D(mm)

4” PN16 (EN 1092-1)

150E2D2

1569

220

6” PN16 (EN 1092-1)

150R0D2

1421

285

6” CL150 (ASME B 16.5)

150R0A1

1485

279

6” CL300 (ASME B 16.5)

150R0A3

1505

318

8” CL150 (ASME B 16.5)

150R2A1

1650

343

8” CL300 (ASME B 16.5)

150R2A3

1670

381

Note) This size is for major item. Unavailable for manufacturing depend on the combination.

Transmitter for remote type (Type FT)

  • Indication contents

Mass flow, Volume flow, Density, Temperature, and any others (Available for select).

4 kind of monitor for operator can be set, and it can indicate several measuring result simultaneously. Indicator has 3 line LCD, and variety of indication is available.

  • Operation

Operated by capacitance touch panel through the glass is available. Set according to the menu by 4 operation keys.

  • Standard output

Analog output: 1 point (4~20mADC/HART7) Digital output: 2 points (Pulse, frequency)

  • Optional plug-in cards (for additional output)

The transmitter has two slots in which plug-in cards can be inserted to provide additional inputs and outputs.

The slots are located on the transmitter motherboard and can be accessed after removing the front housing cover.

The possible combination of plug-in cards

Output code

Additional output code

Slot OC1 Terminals V1 / V2

Slot OC2 Terminals V3 / V4

Output 1

Output 2

G0

G1

×

24 V DC power supply (blue)

G2

×

Passive current output, 4~20 mA (red)

G3

×

×

Passive current output, 4~20 mA (red)

Passive current output, 4~20 mA (red)

G0

DRT

DSN

24 V DC power supply (blue)

Passive digital input (yellow)

G0

DRT

DSG

24 V DC power supply (blue)

Passive digital output (green)

G0

DRT

DSA

24 V DC power supply (blue)

Passive current output, 4~20 mA (red)

G0

DRN

Passive digital input (yellow)

G0

DRN

DSG

Passive digital input (yellow)

Passive digital output (green)

G0

DRN

DSA

Passive digital input (yellow)

Passive current output, 4~20 mA (red)

G0

DRG

DSN

Passive digital output (green)

Passive digital input (yellow)

G0

DRG

DSA

Passive digital output (green)

Passive current output, 4~20 mA (red)

Terminal block

  • IP rating

In accordance with EN 60529:IP65/IP67, NEMA4X

  • Vibration

In accordance with EN 60068-2

10~58Hz, Max deflection 0.15mm(Peak load) 58~150Hz, Max. acceleration 2G(Peak load)

  • Ambient temperature

Standard:-20~70℃ Option:-40~70℃

Note) When operating below -20℃, visibility of the LCD display may be worse.

  • Signal cable (Remote type: between sensor and transmitter) Impedance 100~200Ω

Withstand voltage 120V Outer diameter 6~12mm

Cable design 4 core shielded cable (2 wire pairs as a star-quad cable) Max. signal cable length

0.25mm2

50m

0.34mm2

100m

0.50mm2

150m

0.75mm2

200m

Power

AC Power Terminal

Operating voltage Power consumption

L/N

100~240VAC 50/60Hz

20VA

DC Power Terminal

1+/2-

Operating voltage

11~30VDC

Power consumption

20W

Output

Standard output

Current output

Current output

Active mode

Passive mode

Terminal

Uco(+)/32(-)

31(+)/32(-)

Output signal

4~20mADCor4~12~20mADC Switchable

4~20mADC

Load resistance

250~300Ω

250~600Ω

Source voltage

12~30V

Measuring error

0.1% or less of measured value

Digital output

Digital output

Pulse/frequency output (passive)

Binary output (passive)

Terminal

41(+)/42(-)、51(+)/52(-)

41(+)/42(-)、51(+)/52(-)

Output “closed”

Voltage 3VDC or less 2.5kHz or less:2~30mA

More than 2.5kHz:10~30mA

Voltage 3VDC or less 2~30mA

Output “open”

Voltage 16~30VDC 0.2mA or less

Voltage 16~30VDC 0.2mA or less

Max. frequency

10.5kHz

Pulse width

0.1~2,000ms

Option output

Option (by plug-in card)

Passive current output (red)

Terminal

V1(+)/V2(-)、V3(+)/V4(-)

The plug-in card can be used in slot OC1 or OC2

Output signal

4~20mA

Load resistance

250~600Ω

Source voltage

12~30VDC

Measuring error

0.1% or less of measured value

Digital output (green): Binary output (Passive)

Terminal

V1/V2、V3/V4

The plug-in card can be used in slot OC1 or OC2

Output “closed”

Voltage 3VDC or less 2~30mA

Output “open”

Voltage 16~30VDC 0.2mA or less

Digital input (Yellow)

Terminal

V1(+)/V2(-)、V3(+)/V4(-)

The plug-in card can be used in slot OC1 or OC2

Input “ON”

Voltage 16V~30VDC

Input “OFF”

Voltage 3VDC or less

Internal resistance

6.5kΩ

24VDC Power supply (blue)

Terminal

V1(+)/V2(-)

The plug-in card can be used in slot OC1 only.

Function

For active connection of passive outputs

Output voltage

24VDC at 0mA 17VDC at 25mA

Load rating

25mA, permanently short

circuit-proof

Article

Specification code

Note

Model

FB450

 

Coliolis Mass flow meter / High accuracy type

FB430

 

Coliolis Mass flow meter / General type

 

Explosion Protection Certificate

Y0

 

General Purpose

A2

 

ATEX/IECEx (Zone 2/22)

A1

 

ATEX/IECEx (Zone 1/21)

F2

 

cFMus version Class 1 Div. 2 (Zone 2/21)

F1

 

cFMus version Class 1 Div. 1 (Zone 1/21)

 

Transmitter type / Material / Cable Gland

Y0

 

When select "Unit type"

U1

 

Remote type/Aluminum/1-M20×1.5

U2

 

Remote type/Aluminum/1-NPT1/2

A1

 

Remote type/Stainless/1-M20×1.5

A2

 

Remote type/Stainless/1-NPT1/2

 

 

 

 

 

 

 

 

Meter size / Connection size

015E1

 

015/10A(3/8B)

015R0

 

015/15A(1/2B) : Standard

015R1

 

015/20A(3/4B)

025E1

 

025/20A(3/4B)

025R0

 

025/25A(1B) : Standard

025R2

 

025/40A(1-1/2B)

050E1

 

050/40A(1-1/2B)

050R0

 

050/50A(1B) : Standard

050R1

 

050/65A(2-1/2B)

080E1

 

080/65A(2-1/2B)

080R0

 

080/80A(3B) : Standard

080R1

 

080/100A(4B)

100E1

 

100/80A(3B)

100R0

 

100/100A(4B) : Standard

100R2

 

100/150A(6B)

150E2

 

150/100A(4B)

150R0

 

150/150A(6B) : Standard

150R2

 

150/200A(8B)

 

 

 

 

 

 

Process Connection Type

J1

 

Flange JIS 10K

J2

 

Flange JIS 20K

D2

 

Flange DIN PN16

D4

 

Flange DIN PN40

D5

 

Flange DIN PN63

D6

 

Flange DIN PN100

A1

 

Flange ANSI/ASME B16.5 Class 150

A3

 

Flange ANSI/ASME B16.5 Class 300

A6

 

Flange ANSI/ASME B16.5 Class 600

A7

 

Flange ANSI/ASME B16.5 Class 900

A8

 

Flange ANSI/ASME B16.5 Class 1500

T1

 

In accordance with DIN 32676 Tri-clamp

T3

 

In accordance with ASME BPE Tri-clamp

F1

 

In accordance with DIN 11851 Fitting

Material of Wetted Parts

A1

 

Stainless steel

C1

 

Ni-Alloy (Alloy-C)

 

 

 

 

Flow Calibration

A

 

Flow forward:Liquid±0.4 %, Gas:±1.0 %・・・・・・General type

B

 

Flow forward:Liquid±0.25 %, Gas:±1.0 %・・・・・General type

E

 

Flow forward:Liquid±0.2 %, Gas:±1.0 %・・・・・・General type

C

 

Flow forward:Liquid±0.15 %, Gas:±0.5 %・・・・・High accuracy type

D

 

Flow forward:Liquid±0.1 %, Gas:±0.5 %・・・・・・High accuracy type

J

 

Flow forward/reverse:Liquid±0.4 %, Gas:±1.0 %・・・・・・General type

K

 

Flow forward/reverse:Liquid±0.25 %, Gas:±1.0 %・・・・・General type

N

 

Flow forward/reverse:Liquid±0.2 %, Gas:±1.0 %・・・・・・General type

L

 

Flow forward/reverse:Liquid±0.15 %, Gas:±0.5 %・・・・・High accuracy type

M

 

Flow forward/reverse:Liquid±0.1 %, Gas:±0.5 %・・・・・・High accuracy type

 

Density Calibration

1

 

Density 10 g/L・・・・・General type

3

 

Density 2 g/L・・・・・・High accuracy type

4

 

Density 1 g/L・・・・・・High accuracy type

9

 

Others

 

 

Transmitter Type / Material / Cable Grand

D1

 

Unit type/Aluminum/3-M20×1.5

D2

 

Unit type/Aluminum/3-NPT1/2

D5

 

Unit type/Aluminum/3-NPT1/2(Explosion protection)

D6

 

Unit type/Aluminum/3-M20×1.5(Explosion protection)

Y0

 

When select "Remote type"

 

 

Output

G0

 

Current output 1(AorP), Digital output 1&2(P)、HART

G1

 

Current output 1(AorP), Digital output 1&2(P)、24VDC loop supply、HART

G2

 

Current output 1(A), Digital output 1&2(P), current output 2(P)、HART

G3

 

Current output 1(A), Digital output 1&2(P), current output 2&3(P)、HART

Y0

 

Without: when select remote type

 

Power supply

A

100~230VAC

C

11~30VDC

Y

Without: when select remote type

Sensor option

Article

Additional specification code

Note

 

Additional output 1

DRN

 

1×Digital input

DRG

 

1×Digital output

DRA

 

1×Analog output(P)(4~20mA)

DRT

 

24VDC transmitter loop power supply

 

Additional output 2

DSN

 

1×Digital input

DSG

 

1×Digital output

DSA

 

1×Analog output(P)(4~20mA)

 

Special operation mode

N6

 

Standard + DensiMass : concentration measurement :only 450 type

N5

 

Standard + Filling application

N7

 

VeriMass function: Meter verification : omly 450 type

Pressure-resistance Sensor Housing

PR5

 

Max. burst pressure 6MPa (Include tower length extension)

PR6

 

Max. burst pressure 10MPa(Include tower length extension):Meter size 015

PR7

 

Max. burst pressure 15MPa(Include tower length extension):Meter size 015

 

 

 

 

Signal Cable Length

SC0

 

Without

SC1

 

5m

SC2

 

10m

SC4

 

20m

SC5

 

25m

SC6

 

30m

SC8

 

40m

SCA

 

50m

SCE

 

100m

SCG

 

150m

SCJ

 

200m

TAG No. Plate

T1

 

With TAG No. Plate

Anmbient Temperature Range

TA9

 

-40~70℃

Extend Tower Length

TE1

Tower length extension 1, Meter insukation Single

TE2

Tower length extension 2, Meter insukation Double

Note)  P:Passive mode

 

Remote type (Transmitter)

Article

Specification code

Note

Model

FT450

 

Coliolis Mass flow meter High accuracy type

FT430

 

Coliolis Mass flow meter General type

 

Explosion Protection Certificate

Y0

 

General Purpose

A2

 

ATEX/IECEx (Zone 2/22)

A1

 

ATEX/IECEx (Zone 1/21)

F2

 

cFMus version Class 1 Div 2(Zone 2/21)

F1

 

cFMus version Class 1 Div 1(Zone 1/21)

 

Transmitter type / Material / Cable Grand

R1

 

Remote type/Aluminum/1-M20×1.5

R2

 

Remote type/Aluminum/1-NPT1/2

R5

 

Remote type/Staineless/1-M20×1.5

R6

 

Remote type/Staineless/1-NPT1/2

 

Output

G0

 

Current output 1(AorP), Digital output 1&2(P)、HART

G1

 

Current output 1(AorP), Digital output 1&2(P), 24VDC loop power, HART

G2

 

Current output 1(A), Digital output 1&2(P), Current output 2(P), HART

G3

 

Current output 1(A), Digital output 1&2(P), Current output2&3(P), HART

Power supplu

A

 

100~230VAC

C

11~30VDC

Option                                                      -

Mounting Bracket Shape/ Material

B1

 

2B Pipe mounting / Carbon steel

 

Additional output 1

DRN

 

1×Digital input

DRG

1×Digital output

DRA

1×Analog output(P)(4~20mA)

DRT

24VDC transmitter loop power supply

 

Additional output 2

DSN

 

1×Digital input

DSG

1×Digital output

DSA

1×Analog output(P)(4~20mA)

TAG No. Plate

T1

With TAG No.Plate

Note) A: Active mode P: Passive mode