Scully two-wire optic sensors are purpose-built for liquid petroleum product overfill prevention and point level detection. They are designed to be used with the Scully Intellitrol® and ST-15 series loading rack control monitors. The sensors can also be used with the Scully IntelliCheck® II Monitor. There is no waiting for the control monitors’ permit light to go on because the sensor requires no warm up time. Overfill prevention applications include road tankers, rail cars and storage tanks.
part# | Model | Description | Shaft Length |
09408L1 | SP-TO/MHC(MC) | Two-Wire Optic Sensor, 2″ NPT holder, 2 1⁄8″ Medium Cap | 7″ (175mm) |
09413L1 | SP-TO/MHC (MC) | 12″ (300mm) | |
09416L1 | SP-TO/MHC (MC) | 15″ (375mm) | |
09407L1 | SP-TO/MHCF(MC) | Two-Wire Optic Sensor, flanged holder, 2 1⁄8″ medium cap | 7″ (175mm) |
09412L1 | SP-TO/MHCF (MC) | 12″ (300mm) | |
09415L1 | SP-TO/MHCF (MC | 15″ (375mm) | |
08542 | SD-5CE | 5-Element Electronic Dummy |
Employed on tank trucks with less than 6 compartments (8 in Canada) when not using IntelliCheck II monitor
part# | Model | Description | Shaft Length |
09409L1 | SP-TO | Two-Wire Optic Sensor, (without holder) | 7″ (175mm) |
09414L1 | 12″ (300mm) | ||
09417L1 | 15″ (375mm) | ||
09065 | SP-MHC (MC) | 2″ NPT Threaded Holder Only | |
08265 | SP-MHCF (MC) | Flanged Holder Only |
Operating Temp. Range: | -40°F to +140°F (-40°C to +60°C) |
Petroleum Product Range: | Gasoline blends and light fuel oils |
Exposed Materials: | Aluminum, zinc, borosilicate (Pyrex®) glass, epoxy, conductive nylon, and Viton® seals |
Level Repeatability: | ±1⁄16″ (±1 mm) |
Electrical Leads: | 18” (45cm) long, 22 AWG (0.33 mm²) |
Cable Entry: | Two holes, 1⁄2″ NPT threads |
Detection Level and Size: | The detection level is adjustable; refer to sensor outline drawing above, shown for 7″ shaft length |
Approvals: | The sensor is intrinsically safe for mounting in Class I, Division 1, Groups C & D Hazardous location in accordance with Scully Control Unit approval ratings |