Reelcraft’s power cord reels have a heavy gauge all steel frame and a baked-on powder coat finish that produce a rugged, corrosion-resistant product. A heavy duty and robust collector ring assures maximum conductivity current flow.
Only the highest quality spring steel is used and conditioned to insure there are no imperfections, offering maximum service life. These reels are designed for protection against water or dust, indoor and outdoor. The heavy duty cast aluminum design and powder coat finish combine to produce a rugged, corrosion-resistant product. All models are UL Listed and CSA certified.
Reelcraft’s power cord reels have a heavy gauge all steel frame and a baked-on powder coat finish that produce a rugged, corrosion-resistant product. A heavy duty and robust collector ring assures maximum conductivity current flow.
Only the highest quality spring steel is used and conditioned to insure there are no imperfections, offering maximum service life. These reels are designed for protection against water or dust, indoor and outdoor. The heavy duty cast aluminum design and powder coat finish combine to produce a rugged, corrosion-resistant product. All models are UL Listed and CSA certified.
AYTC is an authorized full service distributor of Reelcraft products. Reelcraft is the leading global manufacturer of the widest range of hose reels, cord reels and cable reels for industrial, commercial and professional applications. Hose reels are used to make hoses, cords, and cables more productive. Whether you need spring-driven, motor driven or hand crank hose reels, we have it all in stock! Call us today!
Model w/ Cord | Accessory | Reel Capabilities | Reel Dimensions (in) | Volts | Amps | Shpg. Wt (lbs) | |||||
Length (ft) | # Cond | AWG | Type | Length | Width | Height | |||||
LH2080 143 | 4 Outlets | 80 | 3 | 14 | SJTW | 11 | 83/4 | 133/4 | 125 | 10 | 15 |
LH3100* | 4 Outlets | 100 | 3 | 10 | STW | 171/4 | 111/8 | 173/4 | 125 | 15 | 13 |
*Does not include cord |
Model w/ Cord | Accessory | Reel Capabilities | Reel Dimensions (in) | Volts | Amps | Shpg. Wt (lbs) | |||||
Length (ft) | # Cond | AWG | Type | Length | Width | Height | |||||
Power Cord Reels | |||||||||||
LD2030 163 9* | Triple receptacle | 30 | 3 | 16 | SJTW | 91/4 | 33/4 | 117/8 | 125 | 10 | 8 |
LD2030 143 9* | Triple receptacle | 30 | 3 | 14 | SJTW | 91/4 | 33/4 | 117/8 | 125 | 13 | 9 |
LG3050 143 9* | Triple receptacle | 50 | 3 | 14 | SJTW | 111/2 | 5 | 151/4 | 125 | 13 | 14 |
LG3040 123 9* | Triple receptacle | 40 | 3 | 12 | SJTW | 111/2 | 5 | 151/4 | 125 | 15 | 14 |
LG3075 143 9Q** | Quad outlet | 75 | 3 | 14 | SJTOW | 111/2 | 5 | 151/4 | 125 | 10 | 20 |
LG3065 123 9Q** | Quad outlet | 65 | 3 | 12 | SJTOW | 111/2 | 5 | 151/4 | 125 | 15 | 24 |
Light Cord Reels | |||||||||||
LD2040 163 2* | Fluorescent | 40 | 3 | 16 | SJTW | 91/4 | 33/4 | 117/8 | 120 | 0.3 | 11 |
LG3050 163 8* | Fluorescent | 50 | 3 | 16 | SJTW | 111/2 | 5 | 151/4 | 120 | 10 | 13 |
LG3050 143 10** | LED | 50 | 3 | 14 | SJTOW | 111/2 | 5 | 151/4 | 125 | 12 | 13 |
For indoor use only. *Models UL listed at 125 Volt 60 HZ single phase. |
Model w/ Cord | Accessory | Reel Capabilities | Reel Dimensions (in) | Volts/ Amps | Volts/ Amps | Shpg. Wt (lbs) | |||||
Length (ft) | # Cond | AWG | Type | Length | Width | Height | |||||
L 4035 163 3 | Single receptacle | 35 | 3 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 13 | —— | 25 |
L 4050 163 3 | Single receptacle | 50 | 3 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 13 | —— | 26 |
L 4545 123 3 | Single receptacle | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 15 | —— | 27 |
L 5550 123 3 | Single receptacle | 50 | 3 | 12 | SJEOOW | 161/2 | 101/2 | 171/2 | 125 / 15 | —— | 44 |
L 70075 123 3 | Single receptacle | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 70 |
L 70100 123 3 | Single receptacle | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 74 |
L 4545 123 3A | Single connector | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 20 | —— | 28 |
L 5550 123 3A | Single connector | 50 | 3 | 12 | SJEOOW | 161/2 | 101/2 | 171/2 | 125 / 20 | —— | 44 |
L 70075 123 3A | Single connector | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | —— | 70 |
L 70100 123 3A | Single connector | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | —— | 74 |
L 4545 123 3B | Twist lock connector | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 20 | —— | 28 |
L 70075 123 3B | Twist lock connector | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | —— | 70 |
L 70100 123 3B | Twist lock connector | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | —— | 74 |
L 4545 123 7 | Duplex outlet box w/GFCI (F) | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 15 | —— | 29 |
L 5550 123 7* | Duplex outlet box w/GFCI (F) | 50 | 3 | 12 | SEOOW | 161/2 | 101/2 | 171/2 | 125 / 20 | —— | 45 |
L 70075 123 7 | Duplex outlet box w/GFCI (F) | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 72 |
L 70100 123 7 | Duplex outlet box w/GFCI (F) | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 76 |
L 4545 123 7A | Duplex outlet box w/GFCI (F) | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 20 | —— | 29 |
L 70075 123 7A | Duplex outlet box w/GFCI (F) | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | —— | 72 |
L 70100 123 7A | Duplex outlet box w/GFCI (F) | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | —— | 76 |
L 4545 123 7B | Duplex outlet box | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 20 | —— | 29 |
L 4050 163 9 | Triple tap receptacle | 50 | 3 | 16 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 13 | —— | 26 |
L 4545 123 9 | Triple tap receptacle | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 15 | —— | 28 |
L 70075 123 9 | Triple tap receptacle | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 71 |
L 70100 123 9 | Triple tap receptacle | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 75 |
L 4545 123 9G | Triple tap w/GFCI (F) | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 15 | —— | 29 |
L 70075 123 9G | Triple tap w/GFCI (F) | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 72 |
L 70100 123 9G | Triple tap w/GFCI (F) | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 15 | —— | 76 |
L 4050 163 X | Flying lead | 50 | 3 | 16 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 13 | 220 / 6.5 | 26 |
L 4545 123 X | Flying lead | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 20 | 220 / 10 | 27 |
L 5550 123 X | Flying lead | 50 | 3 | 12 | SEOOW | 161/2 | 101/2 | 171/2 | 125 / 20 | 220 / 10 | 42 |
L 5750 103 X | Flying lead | 50 | 3 | 10 | SEOOW | 161/2 | 121/2 | 171/2 | 125 / 30 | 220 / 15 | 55 |
L 70075 123 X | Flying lead | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | 220 / 10 | 69 |
L 70100 123 X | Flying lead | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | 220 / 10 | 73 |
L 70100 124 X | Flying lead | 100 | 4 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | —— | 600 / 16 | 75 |
L 4000 | Reel without cord | 50 | 3 | 16 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 13 | 220 / 6.5 | 22 |
L 4500 | Reel without cord | 45 | 3 | 12 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 20 | 220 / 10 | 22 |
L 5500 | Reel without cord | 50 | 3 | 12 | SEOOW | 161/2 | 101/2 | 171/2 | 125 / 20 | 220 / 10 | 35 |
L 5700 | Reel without cord | 50 | 3 | 10 | SEOOW | 161/2 | 101/2 | 171/2 | 125 / 30 | 220 / 15 | 37 |
L 70075 | Reel without cord | 75 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | 220 / 10 | 58 |
L 70100 | Reel without cord | 100 | 3 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | 125 / 20 | 220 / 10 | 58 |
L 70100 124 | Reel without cord | 100 | 4 | 12 | SEOOW | 193/4 | 113/4 | 201/4 | —— | 600 / 16 | 58 |
For indoor non-weather tight applications only. Incandescent bulb 75 watt maximum. *Inlet plug is NEMA5 – 15P configuration. Plug not set for 20 amps. **Auto switch models. All models UL listed at 125 Volt 60 HZ single phase. All models are CSA certified for Canada. |
Model w/ Cord | Accessory | Reel Capabilities | Reel Dimensions (in) | Volts | Amps | Shpg. Wt (lbs) | |||||
Length (ft) | # Cond | AWG | Type | Length | Width | Height | |||||
L NM450 163 X | Flying Lead | 50 | 3 | 16 | SOW | 131/2 | 95/8 | 141/2 | 600 | 9 | 43 |
L NM450 143 X | Flying Lead | 50 | 3 | 14 | SOW | 131/2 | 95/8 | 141/2 | 600 | 13 | 48 |
L NM445 144 X | Flying Lead | 45 | 4 | 14 | SOW | 131/2 | 95/8 | 141/2 | 600 | 11 | 50 |
L NM425 123 X | Flying Lead | 25 | 3 | 12 | SOW | 131/2 | 95/8 | 141/2 | 600 | 18 | 44 |
L NM450 123 X | Flying Lead | 50 | 3 | 12 | SOW | 131/2 | 95/8 | 141/2 | 600 | 18 | 50 |
L NM440 124 X | Flying Lead | 40 | 4 | 12 | SOW | 131/2 | 95/8 | 141/2 | 600 | 14 | 50 |
L NM440 103 X | Flying Lead | 40 | 3 | 10 | SOW | 131/2 | 95/8 | 141/2 | 600 | 22 | 50 |
L NM430 104 X | Flying Lead | 30 | 4 | 10 | SOW | 131/2 | 95/8 | 141/2 | 600 | 16 | 50 |
All models UL listed at 125 Volt 60 HZ single phase. All models are CSA certified for Canada. |
Model w/ Cord | Accessory | Reel Capabilities | Reel Dimensions (in) | Volts/ Amps | Shpg. Wt (lbs) | |||||
Length (ft) | # Cond | AWG | Type | Length | Width | Height | ||||
L 4035 163 1 | Incandescent | 35 | 3 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 10 | 23 |
L 4050 163 1 | Incandescent | 50 | 3 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 10 | 27 |
L 4035 162 2 | Fluorescent | 35 | 2 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 0.3 | 26 |
L 4050 162 2 | Fluorescent | 50 | 2 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 0.3 | 26 |
L 4035 A 163 5** | Rubberized incandescent | 35 | 3 | 16 | SJEOOW | 125/8 | 93/8 | 131/4 | 125 / 15 | 28 |
L 5245 A 163 6X** | Explosion-proof fluorescent | 45 | 3 | 16 | SEOOW | 131/2 | 101/2 | 141/2 | 125 / 0.13 | 39 |
L 4035 163 8 | Fluorescent light and outlet | 35 | 3 | 16 | SJTO | 125/8 | 93/8 | 131/4 | 125 / 13 | 25 |
L 4050 163 8 | Fluorescent light and outlet | 50 | 3 | 16 | SJTO | 125/8 | 93/8 | 131/4 | 125 / 13 | 27 |
L 4035 163 10 | LED | 35 | 3 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 13 | 26 |
L 4050 163 10 | LED | 50 | 3 | 16 | SJTOW | 125/8 | 93/8 | 131/4 | 125 / 13 | 28 |
For indoor non-weather tight applications only. Incandescent bulb 75 watt maximum. *Inlet plug is NEMA5 – 15P configuration. Plug not set for 20 amps. **Auto switch models. All models UL listed at 125 Volt 60 HZ single phase. All models are CSA certified for Canada. |